PanelAccessa PanelWatch line · by S5 System

Guided kit line · 57 panels, one BOM shape

Somebody is being paid to walk to a panel.

Vibration analysers, dust collector controllers, local control stations, analysers, dosing skids, pump stations, dam decant pumps, weighbridges, loadouts. Almost all of them expose UART, Modbus RTU or TCP, 4–20 mA, a dry contact, or a face made of pushbuttons and illuminated indicators — and none of them were designed to be reached from anywhere. PanelAccess puts a remote I/O module across that existing interface and drives it over 4G, NB-IoT, LoRaWAN or WiFi into a web app, PLC, DCS, historian, cloud or on-premises system.

mining and mineral processinggrain and material transferindustrial chemicalremote and large sites

The trip is the cost, and the delay is the damage

A 40 km round trip, an hour and a half of a technician's time and a vehicle is a few hundred dollars before anyone has touched the asset. The panel usually already publishes what is wrong. It simply publishes it somewhere a person has to stand.

What happens today

A fault appears on a local controller. Somebody is called, drives, walks to the asset, reads a lamp or a code, and rings back — or presses reset and drives back.

What the kit changes

The same state is read from a browser or a PLC tag. A documented control input can be driven remotely. A C2 state is reported and escalated, and nobody presses anything.

Four BOM families, 57 applications

The controller, router, power supply, DIN enclosure and harness are shared. What changes is the interface in front of them and the number of I/O points. Families share a landed cost; each kit resolves its own price from its family plus its own I/O variation.

Family A · hardwired takeover

16 digital inputs, 8 relay outputs, PSU, enclosure, harness, 4G or NB-IoT router. Replaces the pushbutton and illuminator face of a legacy controller.

Family B · serial / Modbus

RS-485 or RS-232 gateway to the port the OEM documents, same PSU, enclosure and router. Read by default; writes only where the OEM documents a control input.

Family C · LoRaWAN sensing

A node at the asset and a shared gateway where one exists. No panel penetration and no output at all — level, temperature, vibration, bund, tank.

Family D · C2 monitor only

Isolated inputs only. The module has no output path — not disabled, absent. Fire panels, gas detection, safety interlocks, e-stop status, burner management, flare headers, deluge.

The 57 kits

Each row is a named application: the asset it replaces a walk to, the interface it uses, and the wireless path chosen for that site type. Ask for a written quotation and you get one for the kit you named.

KitAsset and industryExisting interfaceWireless pathClass
VibraAccess
RA-01
Vibration analyser local panel — fixed plant, hard rock and iron oreUART/RS-232 to the analyser + DI/DO takeover of the 6 front-panel keys and 4 LEDs4G LTE (site has no panel LAN, and the analyser cabinet is outside the plant network)C0
full takeover
DustLink
RA-02
Baghouse / dust collector controller — grain receival and bulk transferDI/DO pushbutton + illuminated-indicator emulation on the OEM controller's front panel4G LTE with an external whip antenna at the baghouse roofC0
full takeover
LubeSkid
RA-03
Mill lube skid local panel — concentrator, SAG and ball millsModbus RTU over RS-485 to the skid PLC + 4 DI for local fault lamps4G LTE (skid is 400 m from the nearest switchroom)C0
full takeover
CrusherHyd
RA-04
Crusher lube and hydraulic panel — hard rock crushing circuitDI/DO takeover of start/stop/reset and 8 status lamps; no analogue4G LTE (crusher bench has no usable cable route)C0
full takeover
FlocDose
RA-05
Thickener flocculant dosing station — mineral processing4–20 mA dose feedback + DI/DO for pump run/fault/mode4G LTE (thickener bridge has no network drop)C0
full takeover
ReagentDose
RA-06
Reagent dosing and metering skid — industrial chemical and water treatmentModbus RTU to the skid controller + 2 DI for leak and low-levelNB-IoT (skid sits in a bund with poor LTE coverage and needs a low-power link)C0
full takeover
SumpDewater
RA-07
Sump / dewatering pump station — mining, tunnelling, civilDI/DO takeover of auto/manual/hand and 6 status lamps; float states as DINB-IoT (pit floor, no power for a router beyond the panel's own supply)C0
full takeover
SweepAuger
RA-08
Silo sweep auger local station — grain storage and receivalDI/DO across the local start/stop station with illuminated statusLoRaWAN site gateway (the silo roof already carries a gateway for level nodes)C0
full takeover
AerationFan
RA-09
Silo aeration fan bank — grain storageDI/DO per fan starter with run/fault lamps; 8 fans per kitLoRaWAN (fan bank is 800 m from any building; no cable route)C0
full takeover
WeighbridgePanel
RA-10
Weighbridge local panel and indicator — grain receival, quarry, wasteRS-232 / Modbus RTU to the indicator, plus 2 DI for barrier and loop4G LTE (cabin has a phone line only)C0
full takeover
ShiploaderStation
RA-11
Ship loader local control station — bulk terminalsDI/DO takeover of the local jog/stop/boom keys and 10 status lamps4G LTE with a directional antenna at the loaderC0
full takeover
StackerStation
RA-12
Stacker / reclaimer local control station — stockyardDI/DO to the local station with 12 status lamps and 4 command keys4G LTE (stockyard cable is a maintenance liability)C0
full takeover
BeltScale
RA-13
Belt scale and belt-sway panel — conveyors, bulk transferModbus RTU to the integrator + 4 DI for sway trips4G LTE, or plant WiFi where the switchroom reaches the panelC0
full takeover
CompressorHouse
RA-14
Compressor house control panel — plant air, all industriesModbus RTU to the compressor controller + 4 DI for dryer faults4G LTE (compressor house is a separate building)C0
full takeover
ChillerLocal
RA-15
Chiller local control panel — HVAC, process cooling, cold chainModbus RTU or the OEM's own RS-485 protocol + 3 DIWiFi (plant LAN already reaches the plant room)C0
full takeover
ScrubberDP
RA-16
Scrubber differential-pressure panel — industrial chemical4–20 mA DP transmitter loop + 2 DI for fan run/fault4G LTE (scrubber tower has no network)C0
full takeover
TankFarmBoard
RA-17
Tank farm local gauge board — chemical, fuel, water4–20 mA per level transmitter (8 loops) + 2 DI for high-level switches4G LTE, or LoRaWAN where the farm already has a gatewayC0
full takeover
BundSump
RA-18
Bund / drainage sump pump panel — chemical storage areasDI/DO takeover of the local pump control with high-level and fault DINB-IoT (low power, deep bund, no data appetite)C0
full takeover
BoreField
RA-19
Bore field starter panels — remote water supply, mining camps, agricultureDI/DO per bore starter (4 bores per kit) + 4–20 mA flowNB-IoT (bores are kilometres apart, no power beyond the starter)C0
full takeover
PipelineValve
RA-20
Pipeline valve station local panel — oil & gas, water, slurryDI/DO for open/close/stop and position limit switches + 4–20 mA line pressure4G LTE (stations are spaced tens of kilometres apart)C0
full takeover
TailingsDecant
RA-21
Tailings dam decant pump station — miningDI/DO takeover of the decant pump panel + 4–20 mA pond level4G LTE (dam is beyond site fibre)C0
full takeover
CampPower
RA-22
Camp power station local panel — remote camps, constructionModbus RTU to the genset controller + 4 DI for breaker and fuel4G LTE (camp network is for residents, not plant)C0
full takeover
PumpStationRemote
RA-23
Remote water pump station — utilities, irrigation, mining supplyDI/DO takeover of the local control + 4–20 mA pressure and flowNB-IoT (single low-power link, no site network)C0
full takeover
ScreenDeck
RA-24
Screen deck local control panel — quarry, crushing, recyclingDI/DO takeover of start/stop/reset and 6 status lamps4G LTE (mobile plant, no fixed network)C0
full takeover
ApronFeeder
RA-25
Apron feeder local station — crushing and material transferDI/DO takeover of run/jog/stop and 4 status lamps4G LTE (feeder is on a bench with no cable)C0
full takeover
DryerLocal
RA-26
Grain dryer local control panel — receival, feed millsDI/DO takeover of the dryer keypad functions + 4–20 mA plenum temperature4G LTE (dryer is in a paddock, not the shed network)C0
full takeover
ReceivalPit
RA-27
Grain receival pit local control station — receival and storageDI/DO takeover of pit start/stop, grid and auger status4G LTE (pit is below grade, antenna mounted above)C0
full takeover
TrainLoadout
RA-28
Train loadout local station — bulk terminals, grain, coalDI/DO takeover of load/stop/spout keys and 8 status lamps4G LTE with a mast antenna at the loadoutC0
full takeover
CarDumper
RA-29
Car dumper local panel — coal and bulk terminalsDI/DO takeover of 10 status lamps and 4 command keys, read-first profile4G LTE (dumper house is outside the plant LAN)C0
full takeover
AgitatorLocal
RA-30
Slurry agitator local starter panel — mineral processing, chemicalDI/DO takeover of start/stop and run/fault lamps4G LTE (tank farm edge, no network)C0
full takeover
FilterPress
RA-31
Filter press local control panel — mineral processing, water, chemicalDI/DO takeover of cycle advance/close/open and 8 status lamps4G LTE (press house has no data drop)C0
full takeover
ThickenerRake
RA-32
Thickener rake drive local panel — mineral processing, tailingsModbus RTU to the VSD driving the rake + 4 DI for torque alarms4G LTE (bridge deck, no network)C0
full takeover
AnalyserModbus
RA-33
Process gas analyser — industrial chemical, refinery, cementModbus RTU over RS-485 to the analyser's documented port4G LTE (analyser house is a separate building)C1
read + documented writes
FlowComputer
RA-34
Flow computer — oil & gas, water, slurry pipelinesModbus RTU to the flow computer + 2 DI for batch start/end4G LTE (metering station has no network)C0
full takeover
PowerMeter
RA-35
Energy meter / sub-metering panel — all industriesModbus RTU or Modbus TCP to the meter (up to 8 meters per kit)4G LTE, or plant WiFi where the switchroom is coveredC0
full takeover
VSDParam
RA-36
Variable speed drive panel — pumps, fans, conveyorsModbus RTU to the VSD's documented portplant WiFi (VSD panel is inside a switchroom with coverage)C1
read + documented writes
WeighIndicator
RA-37
Weighing indicator — feed mills, blending, packagingRS-232 continuous or polled output from the indicator4G LTE (mill floor, no data drop)C0
full takeover
PLCBridge
RA-38
Legacy PLC with Modbus TCP — plant-wide, all industriesModbus TCP over the panel's own Ethernet port4G LTE router with an outbound-only tunnel (no inbound port)C0
full takeover
MoistureMeter
RA-39
Online moisture meter — grain, food, mineralsRS-232 or 4–20 mA from the meter4G LTE (dryer or silo area)C0
full takeover
DensityMeter
RA-40
Slurry density meter — mineral processing, tailings4–20 mA or HART digital read to the meter's documented output4G LTE (plant deck, no network)C1
read + documented writes
ChillerBMS
RA-41
Chiller plant BMS gateway — HVAC, process cooling, cold chainModbus TCP to the plant's BMS controllerplant WiFi or 4G LTE failoverC0
full takeover
CompressedAirAudit
RA-42
Compressed-air audit point — manufacturing, mining, food4–20 mA pressure and flow transmitters (2 loops)4G LTE (compressor room has no data drop)C0
full takeover
SiloLevel
RA-43
Silo level — grain, feed, minerals, cementUltrasonic or radar level sensor on a LoRaWAN node (4–20 mA optional)LoRaWAN (roof-mounted, battery, no cable to the silo)C1
read + documented writes
BearingTemp
RA-44
Bucket elevator bearing — grain handling, cement, fertiliserSurface temperature sensor on a LoRaWAN node at each bearing (4 per kit)LoRaWAN (elevator head is 30 m up, no cable)C1
read + documented writes
DamLevel
RA-45
Tailings dam pond level — miningPressure or radar level on a LoRaWAN node with a solar supplyLoRaWAN to a site gateway, or NB-IoT where no gateway reachesC1
read + documented writes
VibrationNode
RA-46
Pump and fan bearing vibration — water, chemical, miningTriaxial vibration on a LoRaWAN node (2 per kit)LoRaWAN (pump station, battery, no cable)C1
read + documented writes
BundLevel
RA-47
Chemical bund liquid level — chemical storage, tank farmsFloat or conductivity sensor on a LoRaWAN node (4 per bund)LoRaWAN (bund has no power or data)C1
read + documented writes
FuelTank
RA-48
Diesel and fuel tank level — camps, gensets, remote sitesLevel sensor on a LoRaWAN or NB-IoT nodeNB-IoT (tank is at a camp edge with no gateway)C1
read + documented writes
ChuteBlockage
RA-49
Transfer chute blockage — conveyors, bulk transferProximity or impact sensor on a LoRaWAN node at the chuteLoRaWAN (chute is inaccessible while running)C0
full takeover
FirePanelWatch
RA-50
Fire indicator panel (FIP) — all sitesIsolated dry-contact inputs from the FIP's documented alarm/fault/isolate relay outputs4G LTE with an outbound-only tunnelC2
MONITOR ONLY
GasDetectWatch
RA-51
Gas detection controller — chemical, mining, oil & gas, wastewaterIsolated 4–20 mA or dry contact from the controller's documented output4G LTE or NB-IoT (whichever the site's own radio survey supports)C2
MONITOR ONLY
SafetyInterlockWatch
RA-52
Safety instrumented interlock (SIL-rated or not) — all process industriesIsolated voltage-free contacts from the interlock's documented status outputs4G LTE, outbound-only tunnelC2
MONITOR ONLY
EStopStatusWatch
RA-53
Conveyor pull-wire / emergency-stop status — mining, bulk transferIsolated dry contacts from the e-stop system's documented status outputsLoRaWAN or 4G LTE (whichever the site radio survey supports)C2
MONITOR ONLY
BurnerManageWatch
RA-54
Burner management panel — dryers, kilns, boilers, asphaltIsolated contacts from the BMS's documented alarm/lockout outputs4G LTE (burner house, no network)C2
MONITOR ONLY
FlareHeaderWatch
RA-55
Flare and vent header local panel — oil & gas, chemicalIsolated contacts for pilot run, valve position, header pressure switch4G LTE or the site's own radio (no new network)C2
MONITOR ONLY
DelugeWatch
RA-56
Deluge and foam system local panel — chemical, fuel, warehousingIsolated contacts for valve-open, pressure-switch and fault4G LTE, outbound-only tunnelC2
MONITOR ONLY
H2SAreaWatch
RA-57
Fixed H2S / toxic gas controller — oil & gas, wastewater, miningIsolated 4–20 mA from the controller's documented output4G LTE or NB-IoT per the site radio surveyC2
MONITOR ONLY

The limit, stated once and enforced in hardware

8 of the 57 kits are C2 and monitor only: FirePanelWatch, GasDetectWatch, SafetyInterlockWatch, EStopStatusWatch, BurnerManageWatch, FlareHeaderWatch, DelugeWatch, H2SAreaWatch.

A fire panel, a gas detection controller, a safety interlock, a burner management panel — these are read, logged and escalated. The C2 kit cannot press the button, suppress an alarm or drive an interlock. Its controller ships with no output path to disable, the app renders no actuate control for it, and a kit with no classification is refused rather than defaulted. That market gets a window, never a hand.

The other 49 kits take over the panel, because the alternative is a person walking to it.

Guided DIY — what you do, what we do, what we will not do

The kit is supplied as parts, installed and commissioned by your licensed electrician. That framing is deliberate: we specify our terminals and the interface the manufacturer publishes, never a terminal inside your panel.

We specify

Every terminal on our own parts; the published interface we connect to (“the OEM documents Modbus RTU at 9600 8N1 over RS-485”); the method to confirm a point and prove isolation; power, fusing, isolation and surge requirements of our assembly; and exactly what the kit will and will not do once connected.

We never specify

Which terminal inside your panel or device; an interface the OEM does not document; mains work of any kind; a connection point identified from a photograph of your panel; or a SIL claim. If the answer depends on hardware we have not seen, the answer is a question back to you.

Request a quotation

Name the asset, the make and model, and the interface the manual documents. You get a written quotation and the interface method for that kit.

Prices are firm, in Australian dollars, ex GST, when quoted in writing.

Questions this page should answer

Does the kit work on a panel with no network port?

That is the case it is built for. Family A takes over the pushbutton and illuminated-indicator face; family B uses the serial port the OEM documents. Neither needs the panel to have Ethernet.

Can it control a fire panel?

No. A fire panel kit is C2: it reports state and raises alerts, and the supplied module has no output path. There is no setting, licence or support agreement that changes that.

Who installs it?

Your licensed electrician installs and commissions it. We supply the parts, the interface documentation and the method; mains work and anything inside your panel is theirs.

Where does the data go?

Your choice of web app, PLC, DCS, historian, cloud or on-premises system. The router opens an outbound tunnel only; no inbound port is opened on the plant network.

Is this a certified product?

No. The kit is supplied as parts for a licensed installer, and no SIL, fire-system or gas-detection certification is claimed or implied. Certified work is a separate paid assessment, not a product.

ThemeCurrency